630 kVA Distribution Transformer

A 630 kVA unit is the size most often specified for medium-sized factories, commercial complexes, utility distribution substations and compact substations. Oil-immersed builds dominate at this rating, with cast resin specified for indoor rooms. We build it oil immersed or cast resin, in 50 Hz and 60 Hz, to IEC 60076.

Indicative specification

Power Rating630 kVA
Primary Voltage3.3 / 6 / 10 / 11 / 13.2 / 13.8 / 15 / 20 / 22 / 33 / 34.5 / 35 kV class
Secondary Voltage480/277 V, 400/230 V, 380/220 V, or customized
PhaseThree-phase
Cooling TypeONAN (oil natural air natural); AN / AF on dry-type builds
Core MaterialHigh-efficiency (CRGO) silicon steel
Connection GroupDyn11, Yyn0, Dyn5
Winding MaterialCopper / Aluminium
Frequency50 / 60 Hz
InsulationMineral oil; epoxy cast resin on dry-type builds
Tap Changer± 2 × 2.5% Off-Circuit Tap Changer (OCTC)
Short-circuit impedance4.5% (typical)
Temperature RiseTop oil ≤ 50 K, winding ≤ 55 K (45 °C ambient)
Noise Level≤ 60 dB at 1 meter
EnclosureHermetically sealed steel tank, weatherproof for indoor and outdoor use
Altitude≤ 1,000 m or customized
Ambient Temperature Range-30 °C to +50 °C
AccessoriesConservator tank, oil level indicator, gas relay, pressure relief valve, etc.
Standards ComplianceDesigned to comply with IEC 60076, IEEE C57 and ANSI C57 as applicable to the order
ApplicationsCommercial and institutional buildings, industrial facilities, oil & gas, solar and wind energy, utility grid connections, data centers, and coastal islands and high-altitude regions.
Transport & InstallationLifting lugs, skid base, galvanized fittings
WarrantyTwo years
Delivery TimeTypically 30 days, depending on quantity
Min. order quantity≥ 1 set

Neighbouring ratings

Is this the right size?

If you know the connected load and the diversity, send both and we will check the rating before you order. Oversizing means paying for capacity that sits idle every hour of the year.

Oil immersed or cast resin?

Questions buyers ask

Typically 30 days after drawing approval, depending on the quantity.
The step between them is decided by the connected load and the diversity, not by rule of thumb. Send both figures and we will size the unit and confirm the impedance.
Yes. Test report, outline drawing and a terminal diagram go out with the unit.
Usually. Send the old nameplate or the outline drawing and we will check the footprint, terminal positions and loss figures before quoting.
Rating, primary and secondary voltage, frequency, vector group, quantity, application and the ambient conditions. A drawing or a nameplate photo settles the rest.

Send us the specification

Rating, primary and secondary voltage, frequency, quantity and the application. We answer within one working day.