4000 kVA Distribution Transformer
A 4000 kVA unit sits at the top of our distribution range. At this size the work is usually utility or renewable: photovoltaic grid-tie step-up duty, battery energy storage and wind collection substations, and large compact substations. We build it oil immersed or cast resin, in 50 Hz and 60 Hz, to IEC 60076.
Indicative specification
| Power Rating | 4000 kVA |
|---|---|
| Primary Voltage | 3.3 / 6 / 10 / 11 / 13.2 / 13.8 / 15 / 20 / 22 / 33 / 34.5 / 35 kV class |
| Secondary Voltage | 480/277 V, 400/230 V, 380/220 V, or customized |
| Phase | Three-phase |
| Cooling Type | ONAN (oil natural air natural); AN / AF on dry-type builds |
| Core Material | High-efficiency (CRGO) silicon steel |
| Connection Group | Dyn11, Yyn0, Dyn5 |
| Winding Material | Copper / Aluminium |
| Frequency | 50 / 60 Hz |
| Insulation | Mineral oil; epoxy cast resin on dry-type builds |
| Tap Changer | ± 2 × 2.5% Off-Circuit Tap Changer (OCTC) |
| Short-circuit impedance | 5.5% (typical) |
| Temperature Rise | Top oil ≤ 50 K, winding ≤ 55 K (45 °C ambient) |
| Noise Level | ≤ 60 dB at 1 meter |
| Enclosure | Hermetically sealed steel tank, weatherproof for indoor and outdoor use |
| Altitude | ≤ 1,000 m or customized |
| Ambient Temperature Range | -30 °C to +50 °C |
| Accessories | Conservator tank, oil level indicator, gas relay, pressure relief valve, etc. |
| Standards Compliance | Designed to comply with IEC 60076, IEEE C57 and ANSI C57 as applicable to the order |
| Applications | Commercial and institutional buildings, industrial facilities, oil & gas, solar and wind energy, utility grid connections, data centers, and coastal islands and high-altitude regions. |
| Transport & Installation | Lifting lugs, skid base, galvanized fittings |
| Warranty | Two years |
| Delivery Time | Typically 30 days, depending on quantity |
| Min. order quantity | ≥ 1 set |
Neighbouring ratings
Is this the right size?
If you know the connected load and the diversity, send both and we will check the rating before you order. Oversizing means paying for capacity that sits idle every hour of the year.
Oil immersed or cast resin?
- Oil immersed: Yes, 4000 kVA oil immersed is a standard build.
- Cast resin: Yes, 4000 kVA cast resin is a standard build.
- Oil units go outside or in a separate substation room; cast resin units go inside the building.
Where a 4000 kVA unit is used
Questions buyers ask
Typically 30 days after drawing approval, depending on the quantity.
Yes — 4 MVA is inside our distribution range, which runs to 33 kV primary and 10 MVA. For higher ratings ask us and we will route the enquiry correctly.
Yes. Test report, outline drawing and a terminal diagram go out with the unit.
Usually. Send the old nameplate or the outline drawing and we will check the footprint, terminal positions and loss figures before quoting.
Rating, primary and secondary voltage, frequency, vector group, quantity, application and the ambient conditions. A drawing or a nameplate photo settles the rest.
Send us the specification
Rating, primary and secondary voltage, frequency, quantity and the application. We answer within one working day.