Dry Type Distribution Transformers

Cast resin dry type distribution transformer builds for indoor installation. Fire-safe, low noise, built to IEC 60076.

Technical specification

Power Rating50 – 6000 kVA
Primary Voltage3.3 / 6 / 10 / 11 / 13.2 / 13.8 / 15 / 20 / 22 / 33 / 34.5 / 35 kV class
Secondary Voltage480/277 V, 400/230 V, 380/220 V, or customized
PhaseThree-phase
Cooling TypeAN
Core MaterialHigh-efficiency (CRGO) silicon steel
Connection GroupDyn11, Yyn0, Dyn5
Winding MaterialCopper / Aluminium
Frequency50 / 60 Hz
InsulationCast resin (dry type)
Tap Changer± 2 × 2.5% Off-Circuit Tap Changer (OCTC)
Short-circuit impedance4 – 6%
Temperature Rise60 – 65 °C
Noise Level≤ 60 dB at 1 meter
EnclosureOptional sheet-steel enclosure, IP00 to IP54
Altitude≤ 1,000 m or customized
Ambient Temperature Range-30 °C to +50 °C
AccessoriesConservator tank, oil level indicator, gas relay, pressure relief valve, etc.
Standards ComplianceIEC 60076, IEEE C57, ANSI C57
ApplicationsCommercial and institutional buildings, industrial facilities, oil & gas, solar and wind energy, utility grid connections, data centers, and coastal islands and high-altitude regions.
Transport & InstallationLifting lugs, skid base, galvanized fittings
WarrantyTwo years
Delivery TimeTypically 30 days, depending on quantity
Min. order quantity≥ 1 set

Typical ratings

50 · 100 · 200 · 315 · 500 · 630 · 800 · 1000 · 1250 · 1600 · 2000 · 2500 kVA and above

Other ratings are built to order. If your rating is not on this list, send it anyway.

How it is built

Options and accessories

Tap changer

Off-circuit ±2 × 2.5%, or an on-load tap changer.

Winding material

Copper or aluminium, to the loss figures you need to meet.

Protection

Pressure relief device, gas relay, oil level and temperature indicators.

Terminations

HV cable box or bushings, LV busbar or cable box.

Monitoring

Winding temperature indicator with alarm and trip contacts.

Finish

Standard industrial paint, or the colour your utility specifies.

Standards and testing

Frequently asked questions

Send the rated power in kVA, primary and secondary voltage, frequency (50 or 60 Hz), cooling type, vector group and the application. Our engineers reply with a technical proposal and price within one working day.
Typically 30 days from order confirmation, depending on order quantity and specification. The exact schedule is confirmed with each quotation.
Two years from dispatch. Warranty terms are stated in the order confirmation.
One set. Single-unit orders and project volumes are both accepted.
Units are designed and tested to comply with IEC 60076, IEEE C57 and ANSI C57 as applicable to the order. Test reports are supplied with each shipment.
Dry-type transformers can be supplied with an enclosure; the protection degree is specified per order according to the installation environment.
Temperature monitoring is supplied as specified in the order, including sensors and monitoring relays where required.

Send us the specification

Rating, primary and secondary voltage, frequency, quantity and the application. We answer within one working day.