Industrial Transformer

Industrial duty is harder than commercial duty.

Talk to an Engineer

Email
info@xsdfftransformer.com

Phone
+86 158 6789 7761

WhatsApp
+852 2416 2620

An industrial transformer feeds production equipment: motors, drives, furnaces, compressors, pumps, process lines and the ancillary building services that keep a plant running.

Industrial duty is harder than commercial duty. Loads are often continuous, unbalanced and rich in harmonics from variable speed drives and rectifiers. Our industrial designs take that into account — through winding configuration, K-factor or harmonic consideration, cooling margin and insulation class — so the transformer does not become the bottleneck that stops your line.

Technical Specifications

ParameterTypical Value
Rated capacity500 – 3150 kVA
Primary voltage11 kV / 22 kV / 33 kV
Secondary voltage400 V / 415 V / 690 V / as required
Frequency50 Hz or 60 Hz
DutyContinuous, IEC 60076-7 / IEEE C57.91 loading guide
CoolingONAN / ONAF / KNAN / AN / AF
InsulationClass F or Class H for high ambient
Winding materialCopper or aluminium
Harmonic considerationK-factor / de-rating for drive loads on request
EnclosureIP23 – IP54, indoor or outdoor
StandardsIEC 60076 / IEEE C57.12

Typical values for this product family. Insert your certified datasheet values before publication — Hebei Youge Electrical Equipment Co., Ltd..

Applications

Advantages

Customization Options

Manufacturing, Testing and Standards

Every unit is built under documented process control and subjected to routine tests before dispatch: winding resistance, voltage ratio and vector group, impedance voltage and load loss, no-load loss and current, applied and induced voltage dielectric tests, and functional checks of accessories. Type tests — including lightning impulse, temperature rise and short-circuit withstand — are available for new designs and project requirements. See our testing and quality control pages.

Frequently Asked Questions

The difference is duty. Industrial loads run longer, start larger motors, and produce more harmonics. Industrial designs therefore use a higher insulation class, more cooling margin and winding configurations that cope with unbalanced and non-linear load.
Often yes. Drives and rectifiers generate harmonics that heat the winding beyond what the fundamental current suggests. If a large share of your load is drives, tell us the share and we will size accordingly or propose a K-rated design.
Yes, within limits. Send us the largest motor rating and starting method (direct-on-line, star-delta, soft starter or VSD) and we will check the voltage dip and thermal effect.
At minimum winding temperature indication with alarm and trip contacts. For oil filled units, oil level and Buchholz relay. Hebei Youge Electrical Equipment Co., Ltd. for the monitoring packages you offer.