Technical Specifications
| Parameter | Typical Value |
|---|---|
| Rated capacity | Hebei Youge Electrical Equipment Co., Ltd. — typical 25 – 500 kVA for pole mounting |
| Primary voltage | 11 kV / 22 kV |
| Secondary voltage | 400 V / 415 V (three phase) or 230 V (single phase) |
| Construction | Oil immersed, sealed, single or three phase |
| Cooling | ONAN |
| Mounting | Single pole, H-frame or platform |
| Protection | Drop-out expulsion fuse, surge arresters, LV breaker where specified |
| Standards | IEC 60076 / IEEE C57.12.20 / local utility standard |
| Installation | Overhead pole, outdoor |
Typical values for this product family. Insert your certified datasheet values before publication — Hebei Youge Electrical Equipment Co., Ltd..
Applications
- Rural and peri-urban distribution
- Agricultural and irrigation supply
- Street and roadway lighting
- Telecommunications and repeater sites
- Temporary construction site power
- Small commercial and village supply
Advantages
- Lowest installed cost per connection for overhead networks
- Fast installation and easy replacement
- Self-cooled, sealed design for minimal maintenance
- Single or three phase options
- Standard protection set: drop-out fuse and lightning arresters
- Suitable for temporary and mobile applications
Customization Options
- Single or three phase
- Pole mounting bracket or platform type
- Primary voltage and tapping
- Fuse and arrester arrangement
- LV termination and metering requirement
Manufacturing, Testing and Standards
Every unit is built under documented process control and subjected to routine tests before dispatch: winding resistance, voltage ratio and vector group, impedance voltage and load loss, no-load loss and current, applied and induced voltage dielectric tests, and functional checks of accessories. Type tests — including lightning impulse, temperature rise and short-circuit withstand — are available for new designs and project requirements. See our testing and quality control pages.