Distribution Transformers for India

Oil-immersed and cast resin distribution transformers built for Indian networks: 3.3, 6.6, 11, 22 and 33 kV primary at 50 Hz, stepping down to 415 V three-phase. We build to the order specification, including IS 1180 where the order calls for it.

Local network data

Distribution circuit voltages3.3 / 6.6 / 11 / 22 / 33 kV
System frequency50 Hz
Secondary voltage415 V three-phase (240 V single phase); 433 V where specified
Typical vector groupDyn11
Standard ratings (IS 1180)250 – 2500 kVA, three-phase, up to 33 kV
Local standardIS 1180 (Part 1) — oil-immersed distribution transformers
Design basisIEC 60076; IS 1180 where the order specifies
Ambient designUp to 50 °C ambient, tropical humidity

IS 1180 (Part 1) covers three-phase oil-immersed distribution transformers up to 2500 kVA at system voltages up to and including 33 kV — inside our distribution range.

Send the state utility or EPC specification and we build to it, vector group and tapping included.

Build specification

PhaseThree-phase
Cooling TypeONAN on oil-immersed builds; AN / AF on dry-type builds
Core MaterialHigh-efficiency (CRGO) silicon steel
Connection GroupDyn11, Yyn0, Dyn5
Winding MaterialCopper / Aluminium
Tap Changer± 2 × 2.5% Off-Circuit Tap Changer (OCTC)
Noise Level≤ 60 dB at 1 meter
EnclosureHermetically sealed steel tank, weatherproof for indoor and outdoor use
Altitude≤ 1,000 m or customized
Ambient Temperature Range-30 °C to +50 °C
Standards ComplianceDesigned to comply with IEC 60076, IEEE C57 and ANSI C57 as applicable to the order
WarrantyTwo years
Delivery TimeTypically 30 days, depending on quantity
Min. order quantity≥ 1 set

Oil immersed or cast resin?

Where these units are used

Questions buyers ask

Where the order specifies IS 1180, yes — IS 1180 (Part 1) covers three-phase oil-immersed distribution transformers up to 2500 kVA at system voltages up to 33 kV. Where the order specifies IEC 60076 instead, we build to that.
3.3, 6.6, 11, 22 and 33 kV at 50 Hz, with 415 V or 433 V secondary as specified. Tell us the utility and we match the tapping range and vector group.
Typically 30 days after drawing approval, depending on the quantity.
Rating, primary and secondary voltage, frequency, vector group, quantity, application and the ambient conditions. A drawing or a nameplate photo settles the rest.

Send us the specification

Rating, primary and secondary voltage, frequency, quantity and the application. We answer within one working day.