{"a":1}
,

160 kVA 33kV Three-Phase Oil-Immersed Distribution Transformer

This 160 kVA oil-immersed transformer steps 33,000 V (33 kV) down to 415 V / 240 V (3-Phase 4-Wire) for Commercial and institutional buildings, industrial facilities, oil & gas, solar and wind energy. Cooling is ONAN (Oil Natural Air Natural), insulation Mineral oil, short-circuit impedance 4.0%. Windings are Copper / Aluminium on a High-efficiency (CRGO) silicon steel core. Top Oil ≤ 50K, Winding ≤ 55K (45°C Ambient) temperature rise and ≤ 60 dB at 1 meter noise level. Enclosure: Hermetically sealed steel tank, weatherproof for indoor and. Specification is confirmed per order, with compliance to IEC 60076, BS 171, SON NIS, NERC Code as applicable to the order. Typical 30-day delivery, two years warranty, MOQ one set.

Technical Parameters & Ratings

IEC / ANSI CertifiedFactory Standard
Power Rating 160 kVA
Primary Voltage 33,000 V (33 kV)
Secondary Voltage 415 V / 240 V (3-Phase 4-Wire)
Phase Three-phase
Cooling Type ONAN (Oil Natural Air Natural)
Core Material High-efficiency (CRGO) silicon steel
Connection Group Dyn11
Winding Material Copper / Aluminium
Frequency 50 Hz
Insulation Mineral oil
Tap Changer ± 2 × 2.5% Off-Circuit Tap Changer (OCTC)
Short-circuit impedance 4.0%
Temperature Rise Top Oil ≤ 50K, Winding ≤ 55K (45°C Ambient)
Noise Level ≤ 60 dB at 1 meter
Enclosure Hermetically sealed steel tank, weatherproof for indoor and outdoor use
Altitude ≤ 1,000 m or customized
Ambient Temperature Range -30 °C to +50 °C
Accessories Conservator tank, oil level indicator, gas relay, pressure relief valve, etc.
Standards Compliance IEC 60076, BS 171, SON NIS, NERC Code
Applications Commercial and institutional buildings, industrial facilities, oil & gas, solar and wind energy
Transport & Installation Lifting lugs, skid base, galvanized fittings
Warranty Two years
Delivery Time Typically 30 days, depending on quantity
Min. order quantity ≥ 1 set

Application Scenarios

  • Rural utility distribution network feeders
  • Industrial and mining site power supply
  • Infrastructure and EPC contractor projects in Africa and MENA
  • Renewable energy grid connection at voltage class

Key Features

  • 160 kVA rated capacity for rural utility and distribution network applications
  • class design suited for Africa, MENA, and IEC-standard grid markets
  • Oil-immersed ONAN structure for stable thermal performance in outdoor environments
  • Copper or aluminum winding options available to suit project budget requirements
  • Off-circuit tap changer with +/-2 x 2.5% or +/-5% range as standard

Technical Highlights

  • The 160 kVA 33kV oil immersed transformer is engineered for outdoor distribution substations. It is built to IEC 60076 with factory routine testing, and can be configured to the voltage, rating, and protection requirements of the project.

Application Scenarios

  • Outdoor distribution substations
  • Industrial plants and processing facilities
  • Utility distribution networks and feeder systems
  • Renewable energy and storage integration points
  • Infrastructure and public works projects

Key Features

  • Sealed tank construction reduces maintenance and oil oxidation
  • High short circuit withstand for industrial duty
  • ONAN cooling for continuous rated operation
  • Wide voltage and impedance configuration to match project requirements
  • Corrosion protected tank for outdoor service

Optional Configurations

  • Voltage ratio and vector group configured to project requirements
  • Impulse level, temperature rise, and insulation class options
  • Winding material and loss level options
  • Enclosure, protection degree, and paint finish options
  • Temperature monitoring, protection, and remote signalling options

Quality & Compliance

  • Manufactured to IEC 60076 with factory routine testing on every unit
  • Type test reports and routine test certificates supplied with delivery
  • ISO 9001 quality management across design, winding, and assembly
  • Third party inspection and pre shipment testing available on request
  • Standard 30 day lead time and 2 year warranty on the delivered unit

How to Order & Request a Quotation

  • Send your rated capacity, primary and secondary voltage, and frequency
  • Confirm the required standard, vector group, and cooling type
  • State the installation environment such as indoor, outdoor, or coastal
  • Note any required protection, monitoring, or enclosure options
  • Our engineering team returns a quotation and drawing for approval

Service & Support

  • Custom design to match non standard voltage and rating requirements
  • Drawing and data sheet issued for approval before production
  • Export packing and documentation for international shipment
  • Technical support during installation and commissioning
  • Spare parts and after sales service for the service life of the unit

Reviews

There are no reviews yet.

Be the first to review “160 kVA 33kV Three-Phase Oil-Immersed Distribution Transformer”

Your email address will not be published. Required fields are marked *

Scroll to Top