Medium Voltage Transformer

Selecting a medium voltage transformer is not only about kVA.

Talk to an Engineer

Email
info@xsdfftransformer.com

Phone
+86 158 6789 7761

WhatsApp
+852 2416 2620

Medium voltage transformers operate on the primary side at 11 kV, 22 kV or 33 kV — the voltage levels used for regional distribution and for large industrial and commercial intake substations.

Selecting a medium voltage transformer is not only about kVA. Insulation level (BIL), vector group, impedance, tapping range and the short-circuit withstand capability of the winding all have to match the network you are connecting to. We engineer each unit against your network data so it can be installed and energised without site modification.

Technical Specifications

ParameterTypical Value
Rated capacity500 – 3150 kVA (higher on request)
Primary voltage11 kV / 22 kV / 33 kV
Secondary voltage400 V / 415 V / 433 V / 690 V
Frequency50 Hz or 60 Hz
BIL / insulation levelPer IEC 60076-3 for the system voltage
Vector groupDyn11, Dyn5, Yyn0 (as specified)
Impedance4% – 8% depending on fault level
CoolingONAN / KNAN / AN / AF
Tap changerOff-circuit ±2 x 2.5% (OLTC on request)
StandardsIEC 60076 / IEEE C57.12
InstallationIndoor substation, outdoor kiosk or pad mount

Typical values for this product family. Insert your certified datasheet values before publication — Hebei Youge Electrical Equipment Co., Ltd..

Applications

Advantages

Customization Options

Manufacturing, Testing and Standards

Every unit is built under documented process control and subjected to routine tests before dispatch: winding resistance, voltage ratio and vector group, impedance voltage and load loss, no-load loss and current, applied and induced voltage dielectric tests, and functional checks of accessories. Type tests — including lightning impulse, temperature rise and short-circuit withstand — are available for new designs and project requirements. See our testing and quality control pages.

Frequently Asked Questions

In power distribution practice, medium voltage generally covers 1 kV up to 36 kV. The most common distribution levels are 11 kV, 22 kV and 33 kV.
It depends entirely on the supply available at your site and on the utility’s distribution standard. Higher primary voltage means lower current and lower cable losses, but requires higher insulation level and more expensive switchgear.
Our focus is the transformer itself. We coordinate the interface — bushings, cable boxes, protection signals — with your switchgear supplier. Hebei Youge Electrical Equipment Co., Ltd. if you also supply packaged substations.
Yes. Send us the nameplate data and, where possible, the dimensional drawing and terminal arrangement. We will confirm a replacement or an equivalent modern design with matching footprint.