Commercial Transformer

In a building, the transformer usually sits close to people — in a basement substation, a rooftop plant room or a compact outdoor kiosk.

Talk to an Engineer

Email
info@xsdfftransformer.com

Phone
+86 158 6789 7761

WhatsApp
+852 2416 2620

Commercial transformers serve buildings rather than process equipment: lighting, lifts and escalators, HVAC plant, kitchens, data rooms, retail tenancy panels and standby systems.

In a building, the transformer usually sits close to people — in a basement substation, a rooftop plant room or a compact outdoor kiosk. That changes the priorities: fire safety, low noise, compact footprint, low losses and clean appearance matter as much as the electrical rating.

Technical Specifications

ParameterTypical Value
Rated capacity500 – 3150 kVA
Primary voltage11 kV / 22 kV / 33 kV
Secondary voltage400 V / 415 V
Frequency50 Hz or 60 Hz
ConstructionDry type cast resin or VPI (indoor) / oil immersed (outdoor)
Fire performanceSelf-extinguishing, halogen-free (dry type)
Sound levelLow-noise design — Hebei Youge Electrical Equipment Co., Ltd. dB(A)
CoolingAN / AF / ONAN / KNAN
EnclosureIP21 – IP54, ventilated or sealed
StandardsIEC 60076 / IEC 60726 / local fire code

Typical values for this product family. Insert your certified datasheet values before publication — Hebei Youge Electrical Equipment Co., Ltd..

Applications

Advantages

Customization Options

Manufacturing, Testing and Standards

Every unit is built under documented process control and subjected to routine tests before dispatch: winding resistance, voltage ratio and vector group, impedance voltage and load loss, no-load loss and current, applied and induced voltage dielectric tests, and functional checks of accessories. Type tests — including lightning impulse, temperature rise and short-circuit withstand — are available for new designs and project requirements. See our testing and quality control pages.

Frequently Asked Questions

Dry type (cast resin or VPI) is the usual choice inside occupied buildings because it needs no oil bund, is self-extinguishing and has lower fire load. Oil immersed is typically used outdoors or in a dedicated, bunded substation.
Sound level depends on rating, flux density and cooling. Tell us the limit imposed by your local code or tenant requirement and we will design and test to it. Hebei Youge Electrical Equipment Co., Ltd. for measured values.
Yes, provided the structure carries the weight and access is available for installation and maintenance. Dry type units are usually preferred for rooftop plant rooms.
Yes. We work from MEP consultant specifications and provide the datasheet, GA drawing, test reports and compliance statement needed for submission and approval.