Why Youge Oil Filled Transformers
Our oil filled distribution transformers use high grade grain oriented silicon steel lamination, oxygen free copper or aluminium windings and a fully sealed corrugated steel tank. The sealed construction keeps the insulating oil isolated from ambient air, which slows insulation ageing and removes the need for periodic oil top-up.
Key Features
- Low Loss Design: Optimised core geometry with step-lap joints keeps no-load loss and load loss within the limits of IEC 60076, reducing total cost of ownership over the service life.
- Hermetically Sealed Tank: Corrugated tank walls absorb oil volume change without a conservator, so the unit is maintenance free and protected against moisture ingress.
- Withstands Extreme Environments: Rated for continuous outdoor operation from -40 °C to +40 °C with anti-corrosion painting and sealed bushings for humid, coastal and dusty sites.
- Short Circuit Strength: Windings are braced and the core is clamped to withstand the mechanical forces of through-fault conditions without deformation.
Oil Filled Distribution Series
16000 kVA Oil Filled Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Oil immersed distribution transformer
10000 kVA Oil Filled Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Oil immersed distribution transformer
6000 kVA Oil Filled Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Oil immersed distribution transformer
5000 kVA Oil Filled Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Oil immersed distribution transformer
4000 kVA Oil Filled Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Oil immersed distribution transformer
3750 kVA Oil Filled Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Oil immersed distribution transformer
3000 kVA Oil Filled Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Oil immersed distribution transformer
2500 kVA Oil Filled Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Oil immersed distribution transformer
2000 kVA Oil Filled Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Oil immersed distribution transformer
1600 kVA Oil Filled Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Oil immersed distribution transformer
1250 kVA Oil Filled Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Oil immersed distribution transformer
1000 kVA Oil Filled Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Oil immersed distribution transformer
Technical Specifications
| Item | Specification |
|---|---|
| Type | Three phase oil immersed distribution transformer |
| Rated Capacity | 25 kVA – 20,000 kVA |
| Primary Voltage | 10 kV / 11 kV / 20 kV / 33 kV / 35 kV |
| Secondary Voltage | 0.4 kV (others on request) |
| Frequency | 50 Hz or 60 Hz |
| Connection Group | Dyn11, Yyn0 (others on request) |
| Cooling Type | ONAN / ONAF |
| Winding Material | Copper or Aluminium (optional) |
| Impedance Voltage | 4.0 % – 6.5 % (customisable) |
| Insulation Class | Class A (oil immersed) |
| Temperature Rise | ≤ 60 K (top oil) |
| Protection Degree | IP54 standard, higher on request |
| Standards Compliance | IEC 60076 / GB 1094 / IEEE C57.12 |
| Noise Level | ≤ 55 dB (rating dependent) |
Note: when ordering beyond the above conditions, please consult our engineering team so we can confirm a suitable design for your project.
Typical Applications
- Utility distribution substations and pole mounted installations
- Industrial plants, manufacturing lines and process facilities
- Commercial buildings, offices, hotels, hospitals and shopping malls
- Renewable energy and mining site power distribution
Customisation Options
- Voltage & Tapping: Off-circuit or on-load tap changer, dual voltage ratio, extended tapping range
- Winding Material: Copper or aluminium windings to suit budget and loss targets
- Cooling Upgrade: ONAF or forced oil circulation for higher continuous loading
- Protection & Monitoring: Buchholz relay, pressure relief valve, oil and winding temperature indicators, remote monitoring interface
- Enclosure & Finish: Anti-corrosion painting systems, higher IP rating, coastal and desert duty finish
How We Support Your Project
- Pre-Sales Technical Consultation: Our engineers review your load list, single line diagram and site conditions to confirm the correct rating, voltage class and construction before you order.
- Customization Support: Winding material, impedance, tapping range, enclosure protection degree and accessory set can all be tailored to your project specification.
- Installation & Commissioning Support: General arrangement drawings, installation manuals and remote engineering assistance for accurate installation and minimal downtime.
- After-Sales Support: Remote troubleshooting, maintenance guidance and fast spare parts availability to keep the transformer in reliable service.
FAQ
What is the service life of a Youge oil filled transformer?
With normal loading and maintenance, an oil immersed distribution transformer is designed for a service life of around 25 to 30 years. Loading profile, ambient temperature and oil quality are the main factors that determine actual life.
What is the lead time for an oil filled transformer?
Standard ratings are normally ready for dispatch within 25 to 35 days after order confirmation. Customised ratings and special accessory requirements may take longer, and we confirm the schedule with the quotation.
Can you supply a transformer to match our existing unit?
Yes. Send us the nameplate photo, single line diagram or the required rating, voltage ratio, impedance and vector group, and our engineers will confirm an equivalent replacement design.
Which industries do you supply?
We supply industrial plants, commercial buildings, hospitals, hotels, data centres, mining operations, renewable energy projects and utility distribution networks.
Why Buyers Choose Youge
- Customised power solutions delivered for international industrial and utility projects
- Trusted by distributors and EPC contractors across multiple export markets
- Routine and type tested in house to IEC 60076 / IEEE C57.12 before dispatch
Request a Quotation
Send us your transformer requirements — capacity, primary and secondary voltage, frequency, quantity and application. Our engineering team will reply with a technical proposal and quotation.
Email info@xsdfftransformer.com | Phone / WhatsApp +86 158 6789 7761 | WhatsApp +852 2416 2620