Youge Pad Mount Transformer Portfolio
Pad mounted transformers place the transformer inside a lockable, tamper resistant enclosure that sits on a concrete pad. The unit is fed from underground cables and is widely used where overhead lines are not acceptable, such as commercial districts, residential developments and public facilities.
Key Features
- Tamper Resistant Enclosure: Lockable aluminium alloy or steel enclosure with a domed top and dead front high voltage compartment for operator safety and public protection.
- Underground Cable Entry: Designed for cable fed primary and secondary connections, keeping the distribution network out of sight.
- Weather and Corrosion Resistant: Powder coated enclosure with louvred ventilation, rated from -35 °C to +40 °C for outdoor ground mounted installation.
- Quiet Operation: Low noise design suitable for residential areas, hotels and public spaces.
- Flexible Configuration: Single phase or three phase, oil immersed or dry type, with loop feed or radial feed connection.
Pad Mounted Series
Single Phase Pad Mounted Transformer (URD Series)
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer
5000 kVA Pad Mount Three Phase Oil Immersed Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer
3750 kVA Pad Mount Three Phase Oil Immersed Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer
3000 kVA Pad Mount Three Phase Oil Immersed Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer
2500 kVA Pad Mount Three Phase Oil Immersed Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer
2000 kVA Pad Mount Three Phase Oil Immersed Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer
1500 kVA Pad Mount Three Phase Oil Immersed Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer
1000 kVA Pad Mount Three Phase Oil Immersed Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer
Technical Specifications
| Item | Specification |
|---|---|
| Type | Ground mounted pad mounted distribution transformer |
| Rated Capacity | 50 kVA – 2,500 kVA (customisable) |
| Phase | Single phase / Three phase |
| Coil Material | Copper / Aluminium |
| Primary Voltage | 10 kV (others on request) |
| Secondary Voltage | 0.4 kV |
| Frequency | 50 Hz / 60 Hz |
| Structure Type | Oil immersed / Dry type |
| Cooling Method | Oil immersed self cooling, ONAN, ONAF |
| Installation Method | Ground mounted on concrete pad |
| Enclosure Material | Aluminium alloy / steel |
| Protection Grade of Enclosure | IP43 (higher on request) |
| Base Height | 300 – 600 mm |
| Operating Temperature | -35 °C to +40 °C |
| Insulation Class | Class H |
| Design Life | 20 – 30 years |
| Noise Level | ≤ 50 dB |
Note: when ordering beyond the above conditions, please consult our engineering team so we can confirm a suitable design for your project.
Typical Applications
- Commercial districts and shopping centres
- Residential developments and apartment complexes
- Hospitals, hotels, schools and public buildings
- Underground distribution networks where overhead lines are not acceptable
Customisation Options
- Enclosure: Aluminium alloy or steel, dead front design, higher IP rating, custom colours
- Connection: Loop feed or radial feed, cable or bushing connection, live front or dead front
- Monitoring: Temperature and pressure monitoring, remote indication interfaces
- Protection: Bayonet fuses, load break switches, surge arresters and fault indicators
- Capacity & Dimensions: Custom rated capacity, base height and enclosure footprint
How We Support Your Project
- Pre-Sales Technical Consultation: Our engineers review your load list, single line diagram and site conditions to confirm the correct rating, voltage class and construction before you order.
- Customization Support: Winding material, impedance, tapping range, enclosure protection degree and accessory set can all be tailored to your project specification.
- Installation & Commissioning Support: General arrangement drawings, installation manuals and remote engineering assistance for accurate installation and minimal downtime.
- After-Sales Support: Remote troubleshooting, maintenance guidance and fast spare parts availability to keep the transformer in reliable service.
FAQ
Where are pad mounted transformers used?
They are used where a ground level enclosure is preferred instead of an overhead or indoor installation, typically in commercial districts, residential developments, hospitals and public facilities fed by underground cables.
What is the difference between dead front and live front?
In a dead front design the high voltage connections are fully enclosed and not accessible when the cabinet is opened, which is the safer and more common arrangement. Live front designs expose the high voltage connectors and are used in some utility networks.
Can the transformer be supplied as dry type?
Yes. The enclosure can house either an oil immersed transformer or a cast resin dry type transformer, depending on the fire safety and environmental requirements of the site.
What is the design life?
The enclosure and transformer are designed for a service life of approximately 20 to 30 years under normal loading and environmental conditions.
Why Buyers Choose Youge
- Customised power solutions delivered for international industrial and utility projects
- Trusted by distributors and EPC contractors across multiple export markets
- Routine and type tested in house to IEC 60076 / IEEE C57.12 before dispatch
Request a Quotation
Send us your transformer requirements — capacity, primary and secondary voltage, frequency, quantity and application. Our engineering team will reply with a technical proposal and quotation.
Email info@xsdfftransformer.com | Phone / WhatsApp +86 158 6789 7761 | WhatsApp +852 2416 2620