Pad Mounted Transformer

Ground mounted pad mounted distribution transformers from 50 kVA to 2,500 kVA in a tamper resistant enclosure, designed for underground distribution and aesthetically sensitive locations.

SKU: YG-PD-CORE Category:

Youge Pad Mount Transformer Portfolio

Pad mounted transformers place the transformer inside a lockable, tamper resistant enclosure that sits on a concrete pad. The unit is fed from underground cables and is widely used where overhead lines are not acceptable, such as commercial districts, residential developments and public facilities.

Key Features

  • Tamper Resistant Enclosure: Lockable aluminium alloy or steel enclosure with a domed top and dead front high voltage compartment for operator safety and public protection.
  • Underground Cable Entry: Designed for cable fed primary and secondary connections, keeping the distribution network out of sight.
  • Weather and Corrosion Resistant: Powder coated enclosure with louvred ventilation, rated from -35 °C to +40 °C for outdoor ground mounted installation.
  • Quiet Operation: Low noise design suitable for residential areas, hotels and public spaces.
  • Flexible Configuration: Single phase or three phase, oil immersed or dry type, with loop feed or radial feed connection.

Pad Mounted Series

Single Phase Pad Mounted Transformer (URD Series)

Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer

5000 kVA Pad Mount Three Phase Oil Immersed Transformer

Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer

3750 kVA Pad Mount Three Phase Oil Immersed Transformer

Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer

3000 kVA Pad Mount Three Phase Oil Immersed Transformer

Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer

2500 kVA Pad Mount Three Phase Oil Immersed Transformer

Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer

2000 kVA Pad Mount Three Phase Oil Immersed Transformer

Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer

1500 kVA Pad Mount Three Phase Oil Immersed Transformer

Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer

1000 kVA Pad Mount Three Phase Oil Immersed Transformer

Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Pad mounted distribution transformer

Technical Specifications

Item Specification
Type Ground mounted pad mounted distribution transformer
Rated Capacity 50 kVA – 2,500 kVA (customisable)
Phase Single phase / Three phase
Coil Material Copper / Aluminium
Primary Voltage 10 kV (others on request)
Secondary Voltage 0.4 kV
Frequency 50 Hz / 60 Hz
Structure Type Oil immersed / Dry type
Cooling Method Oil immersed self cooling, ONAN, ONAF
Installation Method Ground mounted on concrete pad
Enclosure Material Aluminium alloy / steel
Protection Grade of Enclosure IP43 (higher on request)
Base Height 300 – 600 mm
Operating Temperature -35 °C to +40 °C
Insulation Class Class H
Design Life 20 – 30 years
Noise Level ≤ 50 dB

Note: when ordering beyond the above conditions, please consult our engineering team so we can confirm a suitable design for your project.

Typical Applications

  • Commercial districts and shopping centres
  • Residential developments and apartment complexes
  • Hospitals, hotels, schools and public buildings
  • Underground distribution networks where overhead lines are not acceptable

Customisation Options

  • Enclosure: Aluminium alloy or steel, dead front design, higher IP rating, custom colours
  • Connection: Loop feed or radial feed, cable or bushing connection, live front or dead front
  • Monitoring: Temperature and pressure monitoring, remote indication interfaces
  • Protection: Bayonet fuses, load break switches, surge arresters and fault indicators
  • Capacity & Dimensions: Custom rated capacity, base height and enclosure footprint

How We Support Your Project

  • Pre-Sales Technical Consultation: Our engineers review your load list, single line diagram and site conditions to confirm the correct rating, voltage class and construction before you order.
  • Customization Support: Winding material, impedance, tapping range, enclosure protection degree and accessory set can all be tailored to your project specification.
  • Installation & Commissioning Support: General arrangement drawings, installation manuals and remote engineering assistance for accurate installation and minimal downtime.
  • After-Sales Support: Remote troubleshooting, maintenance guidance and fast spare parts availability to keep the transformer in reliable service.

FAQ

Where are pad mounted transformers used?

They are used where a ground level enclosure is preferred instead of an overhead or indoor installation, typically in commercial districts, residential developments, hospitals and public facilities fed by underground cables.

What is the difference between dead front and live front?

In a dead front design the high voltage connections are fully enclosed and not accessible when the cabinet is opened, which is the safer and more common arrangement. Live front designs expose the high voltage connectors and are used in some utility networks.

Can the transformer be supplied as dry type?

Yes. The enclosure can house either an oil immersed transformer or a cast resin dry type transformer, depending on the fire safety and environmental requirements of the site.

What is the design life?

The enclosure and transformer are designed for a service life of approximately 20 to 30 years under normal loading and environmental conditions.

Why Buyers Choose Youge

  • Customised power solutions delivered for international industrial and utility projects
  • Trusted by distributors and EPC contractors across multiple export markets
  • Routine and type tested in house to IEC 60076 / IEEE C57.12 before dispatch

Request a Quotation

Send us your transformer requirements — capacity, primary and secondary voltage, frequency, quantity and application. Our engineering team will reply with a technical proposal and quotation.

Email info@xsdfftransformer.com  |  Phone / WhatsApp +86 158 6789 7761  |  WhatsApp +852 2416 2620

Scroll to Top