Why Youge Dry Type Transformers
Cast resin dry type transformers replace transformer oil with a vacuum cast epoxy resin insulation system. There is no liquid to leak or burn, so the unit can be installed inside a building, close to the load, without an oil containment pit or fire wall.
Key Features
- High Safety Performance: Flame retardant and self extinguishing insulation with no oil, so there is no fire spread or leakage risk in occupied buildings.
- Excellent Environmental Protection: Fully encapsulated windings resist moisture and dust, making the transformer suitable for humid, dusty and polluted environments.
- Maintenance Free Design: No oil testing, no filter changes and no periodic topping up. Only routine cleaning of the cooling ducts is required.
- Low Noise Operation: The cast resin structure damps core vibration, keeping audible noise low enough for hospitals, hotels and residential buildings.
- Flexible Customisation: Capacity from 30 kVA to 6,000 kVA with optional IP23 or higher enclosures, forced air cooling and temperature monitoring.
Dry Type Cast Resin Series
6000 kVA Dry Type Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Cast resin dry type transformer
5000 kVA Dry Type Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Cast resin dry type transformer
4000 kVA Dry Type Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Cast resin dry type transformer
3750 kVA Dry Type Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Cast resin dry type transformer
3000 kVA Dry Type Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Cast resin dry type transformer
2500 kVA Dry Type Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Cast resin dry type transformer
2000 kVA Dry Type Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Cast resin dry type transformer
1600 kVA Dry Type Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Cast resin dry type transformer
1250 kVA Dry Type Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Cast resin dry type transformer
1000 kVA Dry Type Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Cast resin dry type transformer
630 kVA Dry Type Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Cast resin dry type transformer
500 kVA Dry Type Transformer
Coil Material: Copper / Aluminium • Primary Voltage: 10-35 kV • Frequency: 50 Hz / 60 Hz • Cast resin dry type transformer
Technical Specifications
| Item | Specification |
|---|---|
| Type | Cast resin dry type transformer |
| Rated Capacity | 30 kVA – 6,000 kVA |
| Rated Voltage | 10 kV – 35 kV |
| Secondary Voltage | 0.4 kV (others on request) |
| Connection Group | Dyn11 or Yyn0 (optional) |
| Frequency | 50 Hz or 60 Hz |
| Insulation Class | Class F or Class H (optional) |
| Cooling Type | AN (Air Natural) or AF (Air Forced) |
| Impedance Voltage | Approx. 6.5 % (customisable) |
| Winding Material | Copper or Aluminium (optional) |
| Protection Degree | IP00 standard, optional IP23 or higher |
| Standards Compliance | IEC 60076-11 / GB 6450 |
| Noise Level | ≤ 65 dB |
| Temperature Rise | ≤ 115 °C |
Note: when ordering beyond the above conditions, please consult our engineering team so we can confirm a suitable design for your project.
Typical Applications
- Commercial buildings, offices and shopping malls
- Hospitals, hotels and public facilities requiring fire safety
- Industrial plants, machine shops and production lines
- Underground substations, tunnels and confined spaces
Customisation Options
- Enclosure: IP20, IP23, IP31 or higher protection enclosure with ventilation louvres
- Cooling Upgrade: Forced air cooling (AF) to raise continuous capacity by 20-40 %
- Temperature Monitoring: Pt100 sensors and winding temperature controller with alarm contacts
- Voltage & Tapping: Dual voltage ratio and extended tapping range
- Coil Material: Copper or aluminium windings to suit budget and loss targets
How We Support Your Project
- Pre-Sales Technical Consultation: Our engineers review your load list, single line diagram and site conditions to confirm the correct rating, voltage class and construction before you order.
- Customization Support: Winding material, impedance, tapping range, enclosure protection degree and accessory set can all be tailored to your project specification.
- Installation & Commissioning Support: General arrangement drawings, installation manuals and remote engineering assistance for accurate installation and minimal downtime.
- After-Sales Support: Remote troubleshooting, maintenance guidance and fast spare parts availability to keep the transformer in reliable service.
FAQ
Can a dry type transformer be installed indoors?
Yes, that is the main advantage. Because there is no flammable oil, a cast resin dry type transformer can be installed inside a building without an oil pit, fire wall or blast protection.
What is the temperature rise limit?
Standard designs are limited to 115 °C temperature rise with Class H insulation, and the final figure depends on the insulation class and cooling method selected.
Do dry type transformers need maintenance?
Very little. There is no oil to test or replace. Periodic cleaning of the coil surfaces and cooling ducts to remove dust is normally all that is required.
What is the lead time?
Standard dry type ratings are usually ready for dispatch within 25 to 35 days. Custom enclosures and higher protection degrees may extend the schedule, which we confirm with the quotation.
Why Buyers Choose Youge
- Customised power solutions delivered for international industrial and utility projects
- Trusted by distributors and EPC contractors across multiple export markets
- Routine and type tested in house to IEC 60076 / IEEE C57.12 before dispatch
Request a Quotation
Send us your transformer requirements — capacity, primary and secondary voltage, frequency, quantity and application. Our engineering team will reply with a technical proposal and quotation.
Email info@xsdfftransformer.com | Phone / WhatsApp +86 158 6789 7761 | WhatsApp +852 2416 2620